WuXi JinChi Technology Co.,Ltd.
Tel:+86-510-88550456
Fax:+86-510-88550767
Mob:+86-13861805968 Mr Liu
+86-13395176319 Mr Huang
+86-18121528906 Mr Xu
Add:No.218,XiGang Road,XiShan Area,WuXi,JiangSu
Email:Bing.liu@Jinchikeji.com
Website:www.jinchikeji.com

Roof air conditioners are widely used in daily life due to their compact structure, flexible installation, simple control and convenient combination, which can meet the air conditioning needs of different places and are applicable to factories, workshops, shopping malls and various public facilities (such as shopping malls, conference centers, exhibition halls, stadiums, etc.).
Principle of self-cascade refrigeration system:By taking advantage of the characteristic that the boiling points of the co-voltage mixed working medium are different at the same pressure, the cascade refrigeration effect can be achieved with only one compressor. The core principle is as follows: The mixed working medium is compressed by the compressor into high-temperature and high-pressure gas, which then enters the condenser. The high-boiling-point components condense into liquid, while the low-boiling-point components remain in gaseous state. Subsequently, they are separated through a gas-liquid separator. The high-boiling-point liquid working medium after separation is depressified by the throttling valve and then enters the condensing evaporator, serving as the cold source for the low-temperature refrigerant to condense. The low-boiling-point gaseous working medium is cooled and condensed into a liquid in the condenser evaporator, then passes through the throttling valve to reduce pressure and enters the evaporator. After absorbing the user's cooling energy, it evaporates and finally mixes with the uncondensed high-boiling-point working medium vapor, which is then sucked back into the compressor to complete the cycle.
| Model | JAFQD-030 | JAFQD-045 | JAFQD-060 | JAFQD-075 | JAFQD-090 | |
|---|---|---|---|---|---|---|
| Refrigerating capacity(kw) | 30 | 45 | 60 | 75 | 90 | |
| Heating capacity(kw) | 24 | 42 | 56 | 72 | 85 | |
| Circulating air volume(m³/h) | 3000 | 4500 | 6000 | 7500 | 9000 | |
| Static external residual pressure(Pa) | 240 | 300 | 300 | 350 | 350 | |
| Compressor power(kw) | 7.5 | 11.25 | 15 | 18.75 | 22.5 | |
| Fresh air volume | It can be adjusted according to the indoor air exchange volume | |||||
| Humidification capacity (optional) | It is adjustable according to the indoor humidity requirements | |||||
| overall power consumption(kw) | ||||||
| Unit dimensions (length x width x height) | 2400ⅹ2100ⅹ1200 | 2800ⅹ2400ⅹ1500 | ||||
| Unit weight(kg) | 650 | 750 | 1160 | 1270 | 1380 | |