Ambient temperature

Product presentation

Application: It is suitable for safety performance testing of electronic components, providing reliability tests, product screening tests, etc. Meanwhile, through this equipment test, the reliability of the product can be enhanced and quality control of the product can be carried out. The high and low temperature shock test chamber is an essential testing device in fields such as aviation, automobiles, home appliances, and scientific research. It is used to assess and determine the parameters and performance of electrical, electronic, automotive electrical, and material products after temperature environmental shock changes during high and low temperature tests, as well as their adaptability to use. It is suitable for schools, factories, military industries, research and design institutes, and other units.

Mechanical sheet metal structure

All functions are controlled by a computer, which is an independently developed software with a good operation interface, making the operation and monitoring of users simpler and more intuitive. The hold function enables you to temporarily change the values of the program segment while the program is running. You can set the time and parameters on the screen to automatically switch between cooling, heating and cooling transmission according to the set values.
The cold chamber and hot chamber are independently controlled, and the chamber doors are independent of each other, expanding the application scope of the test chamber (one chamber for three purposes).
The insulation effect of the product can be fully guaranteed.
The test chamber door is interlocked with the circulating fan, the blue lift drive, etc., to ensure the safety of the operator. Once the chamber door is opened, the power supply to the circulating fan and the blue lift drive will be automatically cut off.
There is a standard lead wire hole tube on the top of the box, which is convenient for users to introduce sensor wires, detection cables and other types of leads into the box.
The transition time between the low-temperature zone and the high-temperature zone is less than or equal to 15 seconds.
The temperature recovery time is less than or equal to 5 minutes.
Compliant standard: National Military Standard GJB150.3-86; National military Standard GJB150.4-86 National military Standard GJB150.5-86

Parameter list

Parameter list

Model JCCJ-500 JCCJ-010
Temperature range A:-40℃~150℃ B:-55℃~150℃ C:-65℃~150℃
Temperature fluctuation Both the high-temperature room and the low-temperature room are ≤±2℃
The temperature in the sample area fluctuates ≤±0.5℃(At a constant temperature)
Load-bearing capacity of the sample area 20㎏、30㎏、50㎏

Performance index:
Temperature operation control system:

Controller Imported LED digital display (P, I, D+S, S, R.), touch screen microcomputer integrated controller
Heating system Fully independent system, nickel-chromium alloy electric heating type heater
Refrigerating system Fully enclosed air-cooled single-stage compression refrigeration method/Original French "Tecumseh"/fully enclosed air-cooled cascade compression refrigeration method
Circulatory system High-temperature resistant and low-noise air conditioning type motor. Multi-blade centrifugal fan

Environment configuration:

Standard configuration One set of multi-layer heated frosting window with lighting, two sample racks, and one test lead hole (25mm, 50mm)
Safeguard Leakage protection, short circuit, over-temperature, motor overheating, compressor overpressure, overload and overcurrent protection
Temperature conversion time The travel time from the low-temperature zone to the high-temperature zone or from the high-temperature zone to the low-temperature zone is ≤15 seconds


Time of recovery temperature ≤5 minutes (related to the temperature recovery conditions, namely the cooling water temperature, exposure temperature difference, constant temperature time and sample weight)
Temperature shock method Vertical two-box method/vertical three-box method